Benchmark
Summary : RNE678/100-07 2004 Cable
Type 100
|
|
|
|
STANDARD
|
:
|
BS
EN50117-1 1997 Coaxial Cables used in cabled distribution
networks
|
|
Sections
|
:
|
10.2.1, 10.2.2 ,
10.2.4 , 10.4 , 11.1 , 11.5 , 11.6 , 11.7 , 11.8 , 11.9 , 11.10
|
|
|
|
MECHANICAL SPECIFICATION
|
|
|
Inner Conductor
|
:
|
Copper
|
|
|
Diameter Of Inner Conductor
|
:
|
1.00 +/- 0.02mm
|
|
|
Outer Braid/Tape
|
:
|
No Contact Between
Dissimilar Metals
|
|
|
External Diameter over
Sheath
|
:
|
6.55 +/- 0.3mm
|
|
|
Bending Radius
|
:
|
40 mm
|
|
|
Flexing Radius
|
:
|
75 mm
|
|
ELECTRICAL SPECIFICATION
|
|
|
Nominal Impedance
|
:
|
75 Ohms
+/- 3 Ohms
|
|
|
DC Resistance (20°
C)
|
:
|
Inner < 26 Ohms/km
Outer < 15 Ohms/km
|
|
|
Attenuation :
|
|
|
|
|
5 MHz
|
:
|
< 1.6 dB / 100
m
|
|
|
50 MHz
|
:
|
< 4.6 dB / 100
m
|
|
100 MHz
|
:
|
< 6.5 dB / 100
m
|
|
200 MHz
|
:
|
< 9.5 dB / 100
m
|
|
460 MHz
|
:
|
< 15.0 dB / 100
m
|
|
860 MHz
|
:
|
< 19.5 dB / 100
m
|
|
1000 MHz
|
:
|
< 21.5 dB / 100
m
|
|
1750 MHz
|
:
|
< 29.0 dB / 100
m
|
|
2150 MHz
|
:
|
< 32.5 dB / 100
m
|
|
|
|
|
|
Return Loss :
|
|
|
|
5 - 30 MHz
|
:
|
> 23 dB
|
|
30 - 470 MHz
|
:
|
> 23 dB
|
|
470 - 862 MHz
|
:
|
> 20 dB
|
|
862 - 2150 MHz
|
:
|
> 18 dB
|
|
|
|
|
|
Screening Attenuation
:
|
|
|
|
30 - 470 MHz
|
:
|
> 75 dB
|
|
470 - 1000 MHz
|
:
|
> 75 dB
|
|
1000 - 2150 MHz
|
:
|
> 65 dB
|
|
|
|
|
|
Screening Attenuation
following Multiple Bend Test :
|
|
30 - 470 MHz
|
:
|
> 65 dB
|
|
470 - 1000 MHz
|
:
|
> 65 dB
|
|
1000 - 2150 MHz
|
:
|
> 65 dB
|
|
|
|
|
|
Flexing :
Maintain minimum impedance regularity <1%, and screening
performance
|
|
|
|
|
|
Static Bend Test
: Maintain minimum impedance regularity <1%
|
|
|
|
|
|
Crush Resistance
: Maintain impedance regularity <1%
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
Benchmark Summary : RNE678/125-04
2005 Cable Type 125
|
|
|
|
STANDARD
|
:
|
BS
EN50117-1 1997 Coaxial Cables
used in cabled distribution networks
|
|
Sections
|
:
|
10.2.1,
10.2.2 , 10.2.4 , 10.4 , 11.1 , 11.5 , 11.6 , 11.7 , 11.8 ,
11.9 , 11.10
|
|
|
|
MECHANICAL SPECIFICATION
|
|
Inner
Conductor
|
:
|
Copper
|
|
Diameter
Of Inner Conductor
|
:
|
1.25
+/- 0.03mm
|
|
Outer
Braid/Tape
|
:
|
No
Contact Between Dissimilar Metals
|
|
External
Diameter over Sheath
|
:
|
8.0
+/- 0.4mm
|
|
Bending
Radius
|
:
|
50
mm
|
|
Flexing
Radius
|
:
|
100
mm
|
|
ELECTRICAL SPECIFICATION
|
|
Nominal
Impedance
|
:
|
75
Ohms +/- 3 Ohms
|
|
DC
Resistance (20° C)
|
:
|
Inner < 15 Ohms/Km
Outer
< 13.5 Ohms/Km
|
|
Attenuation :
|
|
|
|
5 MHz
|
:
|
< 1.5 dB
/ 100 m
|
|
50 MHz
|
:
|
< 3.5 dB
/ 100 m
|
|
100 MHz
|
:
|
< 5.0 dB
/ 100 m
|
|
200 MHz
|
:
|
< 7.5 dB
/ 100 m
|
|
460 MHz
|
:
|
< 11.5 dB / 100
m
|
|
860 MHz
|
:
|
< 15.5 dB
/ 100 m
|
|
1000
MHz
|
:
|
< 17.0 dB
/ 100 m
|
|
1750
MHz
|
:
|
< 22.8 dB
/ 100 m
|
|
2150
MHz
|
:
|
< 26.0 dB
/ 100 m
|
|
|
|
|
|
Return Loss :
|
|
|
|
5
- 30 MHz
|
:
|
> 23 dB
|
|
30
- 470 MHz
|
:
|
> 23 dB
|
|
470
- 862 MHz
|
:
|
> 20 dB
|
|
862
- 2150 MHz
|
:
|
> 18 dB
|
|
Screening Attenuation :
|
|
|
|
30
- 470 MHz
|
:
|
> 75 dB
|
|
470
- 1000 MHz
|
:
|
> 75 dB
|
|
1000
- 2150 MHz
|
:
|
> 65 dB
|
|
Screening Attenuation following Multiple Bend Test :
|
|
30
- 470 MHz
|
:
|
> 65 dB
|
|
470
- 1000 MHz
|
:
|
> 65 dB
|
|
1000
- 2150 MHz
|
:
|
> 65 dB
|
|
|
|
|
|
Flexing : Maintain
minimum impedance regularity <1%, and screening performance
|
|
|
|
|
|
Static Bend Test : Maintain
minimum impedance regularity <1%
|
|
|
|
|
|
Crush Resistance : Maintain
impedance regularity <1%
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
Benchmark Summary : RNE678/165-03
2004 Cable Type 165
|
|
|
|
STANDARD
|
:
|
BS
EN50117-1 1997 Coaxial Cables
used in cabled distribution networks
|
|
Sections
|
:
|
10.2.1, 10.2.2 , 10.2.4 , 10.4 , 11.1 , 11.5 , 11.6 , 11.7 , 11.8
, 11.9 , 11.10
|
|
|
|
MECHANICAL SPECIFICATION
|
|
Inner
Conductor
|
:
|
Copper
|
|
Diameter
Of Inner Conductor
|
:
|
1.63mm
+/- 0.1mm
|
|
Outer
Braid/Tape
|
:
|
No
Contact Between Dissimilar Metals
|
|
External
Diameter over Sheath
|
:
|
10.1mm
+/- 0.3mm
|
|
Bending
Radius
|
:
|
75
mm
|
|
Flexing
Radius
|
:
|
150
mm
|
|
ELECTRICAL SPECIFICATION
|
|
|
Nominal
Impedance
|
:
|
75
Ohms +/- 3 Ohms
|
|
DC
Resistance (20° C)
|
:
|
Inner < 10.5
Ohms/km
Outer
< 12 Ohms/km
|
|
Attenuation :
|
|
|
|
5 MHz
|
:
|
< 1.0 dB
/ 100 m
|
|
50 MHz
|
:
|
< 3.0 dB
/ 100 m
|
|
100 MHz
|
:
|
< 4.0 dB
/ 100 m
|
|
200 MHz
|
:
|
< 6.0 dB
/ 100 m
|
|
460 MHz
|
:
|
< 9.0 dB
/ 100 m
|
|
860 MHz
|
:
|
< 12.5 dB
/ 100 m
|
|
1000
MHz
|
:
|
< 13.5 dB
/ 100 m
|
|
1750
MHz
|
:
|
< 19.0 dB
/ 100 m
|
|
2150
MHz
|
:
|
< 22.0 dB
/ 100 m
|
|
|
|
|
|
Return Loss :
|
|
|
|
5
- 30 MHz
|
:
|
> 23 dB
|
|
30
- 470 MHz
|
:
|
> 23 dB
|
|
470
- 862 MHz
|
:
|
> 20 dB
|
|
862
- 2150 MHz
|
:
|
> 18 dB
|
|
Screening Attenuation :
|
|
|
|
30
- 470 MHz
|
:
|
> 75 dB
|
|
470
- 1000 MHz
|
:
|
> 75 dB
|
|
1000
- 2150 MHz
|
:
|
> 65 dB
|
|
|
|
|
|
Screening Attenuation following Multiple Bend Test :
|
|
30
- 470 MHz
|
:
|
> 65 dB
|
|
470
- 1000 MHz
|
:
|
> 65 dB
|
|
1000
- 2150 MHz
|
:
|
> 65 dB
|
|
|
|
|
|
Flexing : Maintain
minimum impedance regularity <1%, and screening performance
|
|
|
|
|
|
Static Bend Test : Maintain
minimum impedance regularity <1%
|
|
|
|
|
|
Crush Resistance : Maintain
impedance regularity <1%
|
|
|
|
|
|
|
|
|
|