Benchmark Summary : RNE678/100-07 2004 Cable Type 100

STANDARD

:

BS EN50117-1 1997 Coaxial Cables used in cabled distribution networks

Sections

:

10.2.1, 10.2.2 , 10.2.4 , 10.4 , 11.1 , 11.5 , 11.6 , 11.7 , 11.8 , 11.9 , 11.10

MECHANICAL SPECIFICATION

Inner Conductor

:

Copper

Diameter Of Inner Conductor

:

1.00 +/- 0.02mm

Outer Braid/Tape

:

No Contact Between Dissimilar Metals

External Diameter over Sheath

:

6.55 +/- 0.3mm

Bending Radius

:

40 mm

Flexing Radius

:

75 mm

ELECTRICAL SPECIFICATION 

Nominal Impedance

:

75 Ohms   +/-  3 Ohms

DC Resistance (20° C)

:

Inner  < 26 Ohms/km

Outer < 15 Ohms/km

Attenuation :

5  MHz

:

<   1.6  dB / 100 m

50  MHz

:

<   4.6  dB / 100 m

100  MHz

:

<   6.5  dB / 100 m

200  MHz

:

<   9.5  dB / 100 m

460  MHz

:

< 15.0  dB / 100 m

860  MHz

:

< 19.5  dB / 100 m

1000 MHz

:

< 21.5  dB / 100 m

1750 MHz

:

< 29.0  dB / 100 m

2150 MHz

:

< 32.5  dB / 100 m

Return Loss :

5 - 30 MHz

:

> 23     dB

30 - 470 MHz

:

> 23     dB

470 - 862 MHz

:

> 20     dB

862 - 2150 MHz

:

> 18     dB

Screening Attenuation :

30 - 470 MHz

:

> 75     dB

470 - 1000 MHz

:

> 75     dB

1000 - 2150 MHz

:

> 65     dB

Screening Attenuation following Multiple Bend Test :

30 - 470 MHz

:

> 65     dB

470 - 1000 MHz

:

> 65     dB

1000 - 2150 MHz

:

> 65     dB

Flexing :  Maintain minimum impedance regularity <1%, and screening performance

Static Bend Test :  Maintain minimum impedance regularity <1%

Crush Resistance :  Maintain impedance regularity <1%

             
             
             
   

Benchmark Summary : RNE678/125-04 2005             Cable Type 125

STANDARD

:

BS EN50117-1 1997 Coaxial Cables used in cabled distribution networks

Sections

:

10.2.1, 10.2.2 , 10.2.4 , 10.4 , 11.1 , 11.5 , 11.6 , 11.7 , 11.8 , 11.9 , 11.10

MECHANICAL SPECIFICATION

Inner Conductor

:

Copper

Diameter Of Inner Conductor

:

1.25 +/- 0.03mm

Outer Braid/Tape

:

No Contact Between Dissimilar Metals

External Diameter over Sheath

:

8.0 +/- 0.4mm

Bending Radius

:

50 mm

Flexing Radius

:

100 mm

ELECTRICAL SPECIFICATION

Nominal Impedance

:

75 Ohms   +/-  3 Ohms 

DC Resistance (20° C)

:

Inner  < 15 Ohms/Km

Outer < 13.5 Ohms/Km

Attenuation :

5  MHz

:

<   1.5      dB / 100 m

50  MHz

:

<   3.5      dB / 100 m

100  MHz

:

<   5.0      dB / 100 m

200  MHz

:

<   7.5      dB / 100 m

460  MHz

:

< 11.5  dB / 100 m

860  MHz

:

< 15.5      dB / 100 m

1000 MHz

:

< 17.0      dB / 100 m

1750 MHz

:

< 22.8      dB / 100 m

2150 MHz

:

< 26.0      dB / 100 m

Return Loss :

5 - 30 MHz

:

> 23         dB

30 - 470 MHz

:

> 23         dB

470 - 862 MHz

:

> 20         dB

862 - 2150 MHz

:

> 18         dB

Screening Attenuation :

30 - 470 MHz

:

> 75         dB

470 - 1000 MHz

:

> 75         dB

1000 - 2150 MHz

:

> 65         dB

Screening Attenuation following Multiple Bend Test :

30 - 470 MHz

:

> 65         dB

470 - 1000 MHz

:

> 65         dB

1000 - 2150 MHz

:

> 65         dB

Flexing :  Maintain minimum impedance regularity <1%, and screening performance

Static Bend Test :  Maintain minimum impedance regularity <1%

Crush Resistance :  Maintain impedance regularity <1%

             
             
   
   

Benchmark Summary : RNE678/165-03 2004            Cable Type 165

STANDARD

:

BS EN50117-1 1997 Coaxial Cables used in cabled distribution networks

Sections

:

10.2.1, 10.2.2 , 10.2.4 , 10.4 , 11.1 , 11.5 , 11.6 , 11.7 , 11.8 , 11.9 , 11.10

MECHANICAL SPECIFICATION

Inner Conductor

:

Copper

Diameter Of Inner Conductor

:

1.63mm +/- 0.1mm

Outer Braid/Tape

:

No Contact Between Dissimilar Metals

External Diameter over Sheath

:

10.1mm +/- 0.3mm

Bending Radius

:

75 mm

Flexing Radius

:

150 mm

ELECTRICAL SPECIFICATION

Nominal Impedance

:

75 Ohms +/-  3 Ohms 

DC Resistance (20° C)

:

Inner  < 10.5 Ohms/km

Outer < 12 Ohms/km

Attenuation :

5  MHz

:

<   1.0      dB / 100 m

50  MHz

:

<   3.0      dB / 100 m

100  MHz

:

<   4.0      dB / 100 m

200  MHz

:

<   6.0      dB / 100 m

460  MHz

:

<   9.0      dB / 100 m

860  MHz

:

< 12.5      dB / 100 m

1000 MHz

:

< 13.5      dB / 100 m

1750 MHz

:

< 19.0      dB / 100 m

2150 MHz

:

< 22.0      dB / 100 m

Return Loss :

5 - 30 MHz

:

> 23         dB

30 - 470 MHz

:

> 23         dB

470 - 862 MHz

:

> 20         dB

862 - 2150 MHz

:

> 18         dB

Screening Attenuation :

30 - 470 MHz

:

> 75         dB

470 - 1000 MHz

:

> 75         dB

1000 - 2150 MHz

:

> 65         dB

Screening Attenuation following Multiple Bend Test :

30 - 470 MHz

:

> 65         dB

470 - 1000 MHz

:

> 65         dB

1000 - 2150 MHz

:

> 65         dB

Flexing :  Maintain minimum impedance regularity <1%, and screening performance

Static Bend Test :  Maintain minimum impedance regularity <1%

Crush Resistance :  Maintain impedance regularity <1%